harga Inkubator Bayi Babynest I-700 Ertunc Ozcan

Inkubator Bayi Babynest I-700 Ertunc Ozcan

Berat: 123.0 kg Brand: Ertunc Ozcan SKU: 40000DDM No Registrasi: AKL 20902817545

Dijamin original dan bergaransi

Air mode control 25-37° C
Temperature rise time ( typical @ 22° C ambient) < 45minutes

Harga Inkubator Bayi Babynest I-700 Ertunc Ozcan :

Rp333,985,200.00
Rp300.586.680 10% off
Tersedia cicilan hingga 12 bulan dengan kartu kredit BNI
Quantity:

Produk yang dibeli bersamaan:

Total = Rp300.586.680
( 1 of 1 items selected )

Deskripsi Inkubator Bayi Babynest I-700 Ertunc Ozcan

  • Power requirements AC220V-230/ AC110V-120V, 50/ 60Hz
  • Power requirements 680VA maximum
  • Power outlet AC220V-230V, 50/ 60Hz, Current 2A max
  • AC110V-AC120V, 50/ 60Hz, Current 2Amax
  • Temperature control range and correlative
  • Air mode control 25-37° C
  • Temperature rise time ( typical @ 22° C ambient) < 45minutes
  • Temperature variability < 0.5° C
  • Temperature uniformity ( level mattress) < 0.8° C
  • Alarm
  • Power alarm power failure
  • Motor alarm motor failure
  • Motor run speed too low
  • Air flow stop
  • Sensor alarm Air temperature sensor failure
  • Isolate overheating sensor failure
  • Air flow sensor failed
  • Temperature deviation alarm High/ low air temperature
  • Over temperature alarm Air temperature control mode
  • Activated if incubator temperature
  • Not exceeds 38° C
  • Environment temperature ( not to use in the environment exceed specified) 
  • Operating range + 20-+ 30° C
  • Storage range -40-+ 70° C
  • Environment humidity
  • Operating range 30% RH-75% RH non-condensing
  • Storage range 10kg
  • I.V Pole max. Load 20N
  • Hood max. Load 4kg
  • Infant mattress max. Load 10kg
  • Other specification
  • Infant mattress width 31cm
  • Infant mattress length 63cm
  • Noise level within hood environment < 60dB ( A) 
  • Base on surroundung environment noise below 45dB 
  • Carbon diaxide( Co2) level within the hood less than 0.5% when a mixture of Co2 in air is delivered at 750ml/ min at a point 10cm above the center of the mattress.
  • Air velocity over mattress less than 0.35m/ s
  • Reset Key
  • When the following alarm occurs, press RESET/ SILENT key to silence the alarm for 5 minutes, the alarm will come back automatically after 5 minutes. If alarm condition no longer exists, the alarm will be canceled ( except overheat) ; or press the RESET/ SILENT key twice to cancel the alarm, the equipment will come back to set state
  • Temperature deviation alarm
  • Sensor alarm
  • Motor alarm
  • Over temperature

Diskusi Inkubator Bayi Babynest I-700 Ertunc Ozcan


Tidak menemukan jawaban yang Anda cari? Tanya disini!
Pertanyaan Anda:

Review Inkubator Bayi Babynest I-700 Ertunc Ozcan


Belum ada ulasan.
Perlindungan Pembeli
Full refund jika pesanan tidak diterima
Refund atau tetap miliki produk yang tidak sesuai dengan deskripsi
Rekomendasi Produk
Terakhir Dilihat
Inkubator Bayi Gigante Millenium
16% off
Rp250.139.076
Rp209.355.531
Gel USG Onemed 5 Liter Biru
13% off
Rp217.800
Rp189.000
Variteks 332 Curved Finger Splint
10% off
Rp200.200
Rp180.180
Vagion Steril Onemed Size M
46% off
Rp15.000
Rp8.000